Connect an RS-485 adapter using Web Serial in a supported desktop browser over HTTPS or localhost. Serial data stays on your computer.
Serial connection
RTU uses 8 data bits. Use a driver-supported, automatic-direction USB/RS-485 adapter. Match device baud/parity/stop bits and check A/B wiring, ground and termination.
RTU requests
Only one request can be pending. Polling accepts reads FC01–04 only. Single-send writes and broadcasts require the explicit checkbox below; there are no automatic retries. Timeout stops polling and requires reconnecting before another request. RTU has no transaction ID: a very late identical reply cannot always be distinguished.
Response and trend
—
—
Plots one selected value from FC03/04 responses, up to 200 samples. Chart coordinates use floating point; values outside safe numeric range and non-finite values are excluded. Exact decoded text is retained. Changing decode settings clears the curve.
Serial log (latest 1000 events)
0| UTC | Event | HEX / Details |
|---|