Connect an RS-485 adapter using Web Serial in a supported desktop browser over HTTPS or localhost. Serial data stays on your computer.

Serial connection

RTU uses 8 data bits. Use a driver-supported, automatic-direction USB/RS-485 adapter. Match device baud/parity/stop bits and check A/B wiring, ground and termination.

Disconnected

RTU requests

Only one request can be pending. Polling accepts reads FC01–04 only. Single-send writes and broadcasts require the explicit checkbox below; there are no automatic retries. Timeout stops polling and requires reconnecting before another request. RTU has no transaction ID: a very late identical reply cannot always be distinguished.

Response and trend

—

—

Plots one selected value from FC03/04 responses, up to 200 samples. Chart coordinates use floating point; values outside safe numeric range and non-finite values are excluded. Exact decoded text is retained. Changing decode settings clears the curve.

Serial log (latest 1000 events)

0
UTCEventHEX / Details