devTest.run

  • WebSocket Tools
    • WebSocket Testing Tool
    • SSE Testing Tool
    • Sparkplug B Simulator
    • MQTT WebSocket Client
    • OPC UA Client Simulator
  • Energy Protocol Simulators
    • OCPP 1.6 Simulator
    • OCPP 2.0 Simulator
    • OCPI 2.3.0 Simulator
    • IEEE 2030.5 Simulator
  • Modbus Tools
    • Frame Diagnostics
    • RTU Frame Tools
    • TCP Frame Tools
    • CRC Calculator
    • Register Decoder
    • Address Converter
    • RTU Serial Client
  • Encryption Tools
    • AES Encryption / Decryption
    • DES Encryption / Decryption
    • RSA Encryption / Decryption
  • Conversion Tools
    • Unix Timestamp
    • Time Zone Converter
    • Color Converter
    • Number Base Converter
    • URL Encoder / Decoder
    • Unicode Converter
    • PDF to Image
    • Morse Code
    • Bandwidth Converter
    • IOPS Calculator
    • RAID Calculator & Simulator
    • Speed Converter
  • Other Tools
    • Image Compressor
    • QR Code Generator
    • Regex Tester
    • Quartz Cron Generator
    • JSON Formatter
    • JSON / XML Converter
    • JSON / YAML Converter
    • JSON to Go Struct
    • Hash Tools
      • Text Hash Calculator
      • File Hash Calculator
中文 English
  1. Home
  2. RAID Calculator & Simulator

Choose RAID and add drives; compare capacity, estimate speed or simulate failures below. Use the rack buttons to simulate failures or remove drives.

Required

Select a capacity to add drives

Clear drives

RAID type

RAID types

JBOD combines drives into a storage pool without redundancy. Usable capacity is the sum of all drives, and different drive sizes can be combined.

RAID 0 stripes data across two or more drives for performance and capacity. It has no fault tolerance: a single drive failure loses the entire array.

RAID 1 mirrors data, usually across two drives. Read performance can improve, while writes are similar to a single drive. A two-drive mirror tolerates one drive failure.

RAID 5 uses distributed parity and requires at least three drives. It tolerates one drive failure. Rebuilding a failed drive can substantially reduce read and write performance.

RAID 6 uses dual distributed parity and requires at least four drives. It tolerates two drive failures, at the cost of additional parity overhead.

RAID 10 combines mirroring and striping, requiring at least four drives. Half the raw capacity is usable. Multiple failures can be tolerated provided no mirror group loses all its drives.

RAID 50 stripes across RAID 5 groups and requires at least six drives. It can tolerate one failed drive in each group. Failure tolerance depends on which groups contain the failed drives.

RAID 60 stripes across RAID 6 groups and requires at least eight drives. It can tolerate two failed drives per group. Losing more than two drives in any group can cause array failure.

RAID type and capacity assumptions

Decimal TB; excludes filesystem overhead. RAID 50/60 use two equal groups; an unpaired drive is unused. RAID 10 uses mirror pairs. Except for JBOD, capacity is based on the smallest drive. With four 8 TB drives, RAID 5 provides 24 TB of usable capacity and RAID 10 provides 16 TB before formatting.

Drive type

Consumer and enterprise SSD capacities. 15.36–122.88TB options are enterprise-class capacities.

Results
Add at least drives for the capacity calculator.
Configured logical capacity
Redundancy overhead
Unused

Currently accessible capacity
Failed / rebuilding drives
Additional failures guaranteed tolerable

Remaining tolerance is the minimum across groups, not the sum. Failure location matters for RAID 10/50/60. Configured capacity allocation above does not change when members fail.

RAID Speed Calculator

Healthy-array estimates. Switching HDD/SSD fills editable per-drive examples; enter your actual specifications.

Sequential read
Sequential write (full stripe)
Random read
Random small-block write
Mixed workload
Mixed workload throughput

Model assumptions and formulas

MB/s uses 1,000,000 bytes; KiB uses 1024 bytes. Random read IOPS = active drives × single-drive read IOPS; small-block write IOPS = active drives × single-drive write IOPS ÷ write penalty. Mixed IOPS = active drives ÷ (read share / read IOPS + write share × penalty / write IOPS). Results are capped by the corresponding sequential throughput and array bandwidth.

Write penalties: RAID 0/JBOD = 1, RAID 1 = mirror count, RAID 10 = 2, RAID 5/50 = 4, RAID 6/60 = 6. Parity sequential writes assume full stripes without read-modify-write. Mirror sequential reads use one drive per mirror group; random reads assume balanced requests. JBOD conservatively uses one active drive and has no striping gain.

No cache, CPU/parity overhead, queue depth, filesystem, degraded-array or rebuild-performance model is included. Match the per-drive IOPS measurements to the selected block size. These estimates are not benchmarks or performance guarantees.

RAID Simulator

Selected drives · use the drive buttons; − removes a drive.

Simulation rules

Simulate drive failures, replacement and rebuild completion. This educational simulation does not access disks or manage a hardware controller.

RAID 10 pairs adjacent drives. RAID 50/60 use two equal, contiguous groups. An odd last drive is unused, not a hot spare. Rebuilding drives count as unavailable until completion. Array data loss remains latched until Reset simulation; replacement alone cannot recover lost data.

devTest.run

Practical tools for developers.
Test protocols, inspect data, and get back to building.

Explore all tools →

Protocol tools

  • WebSocket tester
  • SSE tester
  • MQTT client
  • Modbus tools
  • OPC UA client
  • OCPP 1.6 simulator
  • OCPP 2.0 simulator

More to explore

  • RAID calculator
  • Time zone converter
  • IOPS calculator
  • AssetRise ↗
  • AssetRise MCP ↗

Help shape devTest

Missing a tool? Found a bug?
Tell us what would make your workflow better.

Share feedback ↗ Report a bug or suggest a feature on GitHub
© devTest.run. All rights reserved. Back to top ↑